Task

Measuring the moisture of an insulation material in the edge joint of a screed covering

Structural Moisture - Resistance-based measuring
Get in touch
Solution

Choose an electrode

Carrier system: M 6
6 Measuring instruments compatible2 Usecases
M 6-Bi 200
min.0 to max.87 digits
min.0.1 to max.60 wt.-%
min.0.1 to max.12 CM-%

Ranges depend on connected measuring instrument

Carrier system: M 6
6 Measuring instruments compatible2 Usecases
M 6-Bi 300
min.0 to max.87 digits
min.0.1 to max.60 wt.-%
min.0.1 to max.12 CM-%

Ranges depend on connected measuring instrument

one of these measuring instruments

32 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 200 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0.3 to 25 wt.-%
0.3 to 12 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
21 Electrodes selectable
BL E
0.1 to 42.2 wt.-%
0.1 to 9.6 CM-%
0.7 to 60 wt.-%
2.3 to 87 digits
0 to 200 digits
5.5 to 58 % (dry mass)
-50 to 250 °C
-50 to 350 °C
21 Electrodes selectable
HB 30
4 to 30 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
-20 to 199.9 °C
29 Electrodes selectable
HT 85 T
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
-20 to 200 °C
-50 to 250 °C
-50 to 350 °C
37 Electrodes selectable
UNI 2
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C
41 Electrodes selectable
RTU 600
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C

Your question about our products

Stay informed about
GANN products & services