Wood Moisture
Structural Moisture - supported by measuring instrument, but no respective accessories are included in this packageStructural Moisture - supported by measuring instrument, but no respective accessories are included in this package
Air Humidity
Air Temperature
Surface Temperature - supported by measuring instrument, but no respective accessories are included in this packageSurface Temperature - supported by measuring instrument, but no respective accessories are included in this package
Material Temperature - supported by measuring instrument, but no respective accessories are included in this packageMaterial Temperature - supported by measuring instrument, but no respective accessories are included in this package
Air Speed - not supported

Package
RTU 600 - Set 4

Ref.Nr. 30002685
DescriptionUsecases
DescriptionUsecases
RTU 600 - Set 4

Package contents

Measuring ranges

Display by clicking on the electrode or measuring device next to the application area.
Included devices & accessories
Wood Moisture

In combination with the included RTU 600
Resistance
4 to 100 % (dry mass)
Structural Moisture - supported by measuring instrument, but no respective accessories are included in this packageStructural Moisture - supported by measuring instrument, but no respective accessories are included in this package
Available accessories for Structural Moisture
In combination with the included RTU 600
Resistance
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
12 Measuring instruments compatible2 Usecases
M 20
6 Measuring instruments compatible
M 6
Carrier system: M 20
12 Measuring instruments compatible2 Usecases
M 20-OF 15
6 Measuring instruments compatible
M 21-100
6 Measuring instruments compatible
M 21-250
6 Measuring instruments compatible2 Usecases
M 25-100
6 Measuring instruments compatible2 Usecases
M 25-300
Carrier system: M 6
6 Measuring instruments compatible2 Usecases
M 6-Bi 200
Carrier system: M 6
6 Measuring instruments compatible2 Usecases
M 6-Bi 300
Carrier system: M 20, M 6
6 Measuring instruments compatible2 Usecases
M 20-Bi 200
Carrier system: M 20, M 6
6 Measuring instruments compatible2 Usecases
M 20-Bi 300
Carrier system: M 6, M 20
6 Measuring instruments compatible
M 6-150
Carrier system: M 6, M 20
6 Measuring instruments compatible
M 6-250
Capacitive
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
4 Measuring instruments compatible2 Usecases
B 50
4 Measuring instruments compatible2 Usecases
B 60
4 Measuring instruments compatible
LB 71
Air Humidity

Capacitive
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
Air Temperature

Band Gap
-20 to 80 °C
±0.5 (-10 to 40 °C) Sensor Accuracy
Surface Temperature - supported by measuring instrument, but no respective accessories are included in this packageSurface Temperature - supported by measuring instrument, but no respective accessories are included in this package
Available accessories for Surface Temperature
In combination with the included RTU 600
Pt100
-50 to 600 °C
4 Measuring instruments compatible
OT 100
3 Measuring instruments compatible
OTW 480
4 Measuring instruments compatible
OTW 90
Infrared
-20 to 199.9 °C
4 Measuring instruments compatible
IR 40 EL
Material Temperature - supported by measuring instrument, but no respective accessories are included in this packageMaterial Temperature - supported by measuring instrument, but no respective accessories are included in this package
Available accessories for Material Temperature
In combination with the included RTU 600
Pt100
-50 to 600 °C
4 Measuring instruments compatible
ET 10
  • sensor pipe: 100 mm length
  • up to 250 °C
4 Measuring instruments compatible
ET 50
  • sensor pipe: 120 mm length
  • up to 300 °C
4 Measuring instruments compatible
FT 10
  • Connection cable: 10 m length
  • up to 120 °C
4 Measuring instruments compatible
FT 2
  • Connection cable: 2 m length
  • up to 120 °C
4 Measuring instruments compatible
FT 20
  • Connection cable: 20 m length
  • up to 120 °C
4 Measuring instruments compatible
FT 30
  • Connection cable: 30 m length
  • up to 120 °C
4 Measuring instruments compatible
FT 5
  • Connection cable: 5 m length
  • up to 120 °C
4 Measuring instruments compatible
TT 30
  • sensor pipe: 230 mm length
  • up to 350 °C
4 Measuring instruments compatible
TT 40
  • sensor pipe: 480 mm length
  • up to 350 °C
3 Measuring instruments compatible
TT 480
  • sensor pipe: 480 mm length
  • up to 600 °C
3 Measuring instruments compatible
TT 600
  • sensor pipe: 600 mm length
  • up to 600 °C
Air Speed - not supported

The meaning of the icons

A filled icon = Measuring task is supported by the instrument unit - the respective accessories are included in the package.

A half filled icon = Measuring task is supported by the instrument unit - but this package does not include the respective accessories. This means you can expand the scope of use cases at any time by purchasing additional electrodes & probes.

A transparent icon = Measuring task is not supported by the instrument unit.

Description

This set includes the M 18 ram-in probe for resistance-based moisture measurement of various types of wood and wood-based materials up to a thickness of 180 mm. Also included is the RF-T 28 EL climate probe for humidity and air temperature measurements.

The Hydromette RTU 600 is a multifunctional device with a comprehensive wood moisture measuring range and with extended possibilities for measuring building moisture. It also offers the possibility of carrying out air humidity and temperature measurements with a wide variety of probes. It is therefore (particularly) suitable for painters, drywall installers, parquet and panel layers, parquet factories, wood processing companies, technical wood drying, construction companies, architects, experts and building authorities.

The probes and the measuring device are supplied in a convenient carrying case, together with the measuring cable required for operation.

Your question about this product

Stay informed about
GANN products & services