Stick-in Electrode Pin PairM 6-150
Ref.Nr. 31003706
Extra thin probes for measuring moisture content over expansion joints or through intersecting tile joints
Description
The Stick-in electrode pins M 6-150 are used for measuring the moisture content in building and insulating materials. Due to the extra thin probes (150 x 3 mm Ø) it is possible to measure over expansion joints or through intersecting tile joints.
Measuring ranges
Structural Moisture
The electrode pair can be used with all hydromettes based on the resistance measurement method.
Resistance-based measuring
Measuring ranges
min.0 to max.87 digits
min.0.1 to max.60 wt.-%
min.0.1 to max.12 CM-%
The actual measuring range depends on the connected measuring instrument.
Show compatible measuring instrumentsSpecifications
- The tips are uninsulated and thus provide a large contact area. This reduces the risk of incorrect measurements and increases the reliability of the measurement results
- Ø 3 mm
Length | 0.15 m0.492 ft (0.15 m) |
Compatible instrumentsCan be used with these measuring instruments
4 to 100 % (dry mass)
0 to 200 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0.3 to 25 wt.-%
0.3 to 12 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s