Structural Moisture

Stick-in Electrode Pin Pair
M 6-150

Ref.Nr. 31003706
Extra thin probes for measuring moisture content over expansion joints or through intersecting tile joints 
Description
Description
M 6-150

Description

The Stick-in electrode pins M 6-150 are used for measuring the moisture content in building and insulating materials. Due to the extra thin probes (150 x 3 mm Ø) it is possible to measure over expansion joints or through intersecting tile joints.

Measuring ranges

Structural Moisture

Structural Moisture

The electrode pair can be used with all hydromettes based on the resistance measurement method.
Resistance-based measuring
Resistance-based measuring
Measuring ranges
min.0 to max.87 digits
min.0.1 to max.60 wt.-%
min.0.1 to max.12 CM-%

The actual measuring range depends on the connected measuring instrument.

Show compatible measuring instruments

Specifications

  • The tips are uninsulated and thus provide a large contact area. This reduces the risk of incorrect measurements and increases the reliability of the measurement results
  • Ø 3 mm
Length0.15 m0.492 ft (0.15 m)

Carrier SystemNeeds one of these carrier systems

6 Measuring instruments compatible
M 6
12 Measuring instruments compatible2 Usecases
M 20

Compatible instrumentsCan be used with these measuring instruments

32 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 200 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0.3 to 25 wt.-%
0.3 to 12 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
21 Electrodes selectable
BL E
0.1 to 42.2 wt.-%
0.1 to 9.6 CM-%
0.7 to 60 wt.-%
2.3 to 87 digits
0 to 200 digits
5.5 to 58 % (dry mass)
-50 to 250 °C
-50 to 350 °C
21 Electrodes selectable
HB 30
4 to 30 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
-20 to 199.9 °C
29 Electrodes selectable
HT 85 T
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
-20 to 200 °C
-50 to 250 °C
-50 to 350 °C
37 Electrodes selectable
UNI 2
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C
41 Electrodes selectable
RTU 600
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C

Your question about this product

Stay informed about