Wood Moisture

Modification Set
M 20-DS 16

Ref.Nr. 31004310
For moisture measurements in wood of up to 30 mm in thickness
Description
Description
M 20-DS 16

Description

The modification set  is used for moisture measurements in wood of up to 30 mm in thickness. The particularly slim pins (1.6 mm [Ø]) leave hardly visible punctures in the material (e.g. in mopboards or veneer)

Measuring ranges

Wood Moisture

Wood Moisture

The modification set can be used with all hydromettes based on the resistance measurement method.
Resistance-based measuring
Resistance-based measuring
Measuring ranges
min.4 to max.100 % (dry mass)
min.3.1 to max.41 % water content

The actual measuring range depends on the connected measuring instrument.

Show compatible measuring instruments

Specifications

Consisting of:

  • 2 cap nuts M 20-05 (Ø 1.6 mm)
  • 50 replacement pins (Order no. 31004600)

Carrier SystemNeeds one of these carrier systems

12 Measuring instruments compatible2 Usecases
M 20

Compatible instrumentsCan be used with these measuring instruments

32 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 200 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0.3 to 25 wt.-%
0.3 to 12 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
6 Electrodes selectable
BL H 40
5 to 40 % (dry mass)
8 Electrodes selectable
BL H 42
5 to 40 % (dry mass)
5.7 to 40 % (dry mass)
5.0 to 40 % (dry mass)
7 Electrodes selectable
BL HT 70
5 to 70 % (dry mass)
3.1 to 41 % water content
-50 to 250 °C
6 Electrodes selectable
BL A plus
5 to 50 % (dry mass)
5 to 70 % (dry mass)
21 Electrodes selectable
BL E
0.1 to 42.2 wt.-%
0.1 to 9.6 CM-%
0.7 to 60 wt.-%
2.3 to 87 digits
0 to 200 digits
5.5 to 58 % (dry mass)
-50 to 250 °C
-50 to 350 °C
6 Electrodes selectable
H 35
4 to 30 % (dry mass)
6 Electrodes selectable
HT 65
4 to 60 % (dry mass)
21 Electrodes selectable
HB 30
4 to 30 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
-20 to 199.9 °C
29 Electrodes selectable
HT 85 T
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
-20 to 200 °C
-50 to 250 °C
-50 to 350 °C
41 Electrodes selectable
RTU 600
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C

Replacement parts

Your question about this product

Stay informed about
GANN products & services